Following climate
factors are important for climate-related building:
The
basis for climate-related building is the combination of strategies of
traditional architecture and modern development. For strategies and concepts
of traditional architecture of the different climate zones.
Traditional
building concepts cannot be completely adopted to the architecture of the metroplitan
areas of our complex industrial society. But traditional architecture
demonstrates the various possibilities influencing the indoor climate by
structural measures without additional appliances and with a mimimum of
energy.
The following table provides a reference
guides to the main climatic zones as well as the key design responses for
each climate:
*only
in case of no artificial cooling
|
1.
Polar and Subpolar Climate
The
buildings of this climatic zone serve as protection against cold in the first
instance. Effective heating systems are very important. These heating systems
require energy, but passive design features given below help to reduce the
energy required. Multi-layered wall and roof structures or massive
constructions are considered to be climate- related building envelopes.
Building elements exposed to weather shall consist of weatherproof materials.
basic constructional requirements:
- protection
against cold (heat insulation)
- protection
against storms
- protection
against humidity, especially around roof areas
- if
possible use solar energy in summer
Building
Location, Building Surroundings
The temperatures of building's
surrounding influence the annual amount of energy necessary to heat the
building.
- wind-protected
locations reduce heat loss
- usage
of vegetation and topography as natural windbreak
Building Shape
- optimised
A/V-ratio for reduction of heat transfer by building envelope
- roof overhangs and steep roof pitches (especially on north
facades) shed rain and snow away from the house
and prevent premature deterioration of exterior finish materials (northern
hemisphere)
Building Orientation
Depending on the main wind direction, the
main facade should be oriented to the south (northern hemisphere) or to south
on the southern hemisphere in order to achieve maximum solar gains.
- sun-exposed
facades with short roof overhang on the south-facing facade (northern
hemisphere)
- south-facing
building openings (northern hemisphere) with insulated shutters or roller
shutters
- protection
against north and north-west
Zoning of
Buildings
Zoning implies the location of rooms with
higher heating needs such as living areas on the south side, while the north
side accommodates function and utility rooms. Garages and secondary rooms
oriented to the north act as thermal buffer zones. Attics, basement rooms and
entrance porches are thermal buffer zones between inside and outside as well.
- include
thermal buffer zones
- porched
entrances areas
- living
areas are located in the south, whereas function and utility rooms are
located in the north
Walls and
Roof
- multi-layered
wall and roof structures or massive constructions with low U-value
- include
snow loads
- vapour
barrier should be placed on the inside
- choose
jointless and airtight constructions
- protect
building elements against humidity, especially in roof areas
- use
double or if necessary triple glazing
Windows
- insulated
glazing with low proportion of frame and appropriate U-values (quality of
glazing, proportion of frame, edge seal)
- glazing
with appropriate g-value (SHGC) for solar gains
- appropriate
apertures (large south-facing windows, small north-facing windows)
- insulated shutters or roller shutters
2. Temperate Climate
Moderate climates are determined by
distinctive seasonal fluctuations with strong temperature variations between
summer and winter. The climatic conditions vary from region to region. Decisive
factors are continentality, maritime impacts, latitude and elevation above sea
level. The most buildings of this climatic zone have to meet the following
basic requirements:
- protection
against cold in winter (heat insulation)
- protection
against overheating in summer
- protection
against precipitation
- if
possible use solar energy in summer
Building
Location, Building Surroundings
The temperatures of building's
surrounding influence the annual amount of energy necessary to heat the
building.
- wind-protected
south slopes reduce heat losses
- fresh
air corridors provide ventilation and improve urban thermal environment,
broad streets and open building development contribute to better
ventilation
- usage
of vegetation as natural windbreak or wind-guiding element
- vegetation
around the building improves the microclimate (humidity, temperature,
dust, air pollutants)
Building Shape
Temperature compensation between building
and its surroundings is influenced by building shape and building orientation.
- choose
a compact shape
Building Orientation
- orientation
of the building subject to solar access
- south-facing
main facade and south-facing apertures for maximum solar gains (northern
hemisphere)
- protection
against north and north-west (northern hemisphere)
- include
the possibility of cross ventilation in summer
Zoning of Buildings
The rooms are classified according to
their function and time of usage. Zoning implies the location of rooms with
higher heating needs on the sunny side, while the shady side accommodates
function rooms.
- function
rooms are located in the north, whereas the living area is located in the
south
- rooms
of low temperatures act a thermal buffer between inside and outside
- include
entrance porches (as thermal buffer zones)
Walls and
Roof
- multi-layered
wall and roof structures or massive constructions with low U-value
- vapour
barrier should be placed on the inside
- choose
jointless and airtight constructions
- choose
shape of roof, roof overhangs and roof drainage according local conditions
(amounts of precipitation and snow loads)
- use
insulated glazing
Windows
- insulated
glazing with low proportion of frame and appropriate U-values (quality of
glazing, proportion of frame, edge seal)
- glazing
with appropriate g-value (SHGC) for solar gains
- appropriate
apertures (large south-facing windows, small north-facing windows)
- orientation
of windows and position of the window in connection with interior spaces
for good daylighting: clerestories, skylights and high windows improve the
brightness of a room; windows in the centre of the wall distribute the
light better in the depth of the room than corner windows
- insulated
shutters or roller shutters only if necessary
Shading
During the hot season, shading devices
are very important: Shading devices have to be chosen according to window
orientation:
- protection
against noon sun angle : horizontal shading (for south facades, northern
hemisphere)
- protection
against low hanging sun : vertical louvers or fins (for east and
especially west facades)
- For
maximum solar gains, it is a wise idea to choose adjustable shading
devices wherever possible
3.
Subtropical Climate
Subtropical climate zones are determined
by distinctive seasonal fluctuations with temperature variations and different
amounts of precipitation in summer and winter.
basic constructional requirements:
- protection
against overheating in summer
- using
of natural air flow for cooling in summer
- protection
against precipitations
- shading
of exterior spaces (plantings)
- protection
against winterly cold (depending on the region)
Building
Location, Building Surroundings
The temperatures of building's
surrounding influence the annual amount of energy necessary to heat or cool the
building.
- wind-exposed
locations for effective ventilation in summer
- fresh
air corridors provide ventilation and improve urban thermal environment,
broad streets and open building development contribute to better
ventilation
- usage
of vegetation as natural windbreak or wind-guiding element
- vegetation
around the building improves the microclimate (humidity, temperature,
dust, air pollutants)
- planting
provides shade; shade structures to lower ground temperatures
- include
evaporative cooling of water bidies and water features
- provide
appropriate screened, shaded, rain protected outdoor living spaces
Building Shape
Temperature compensation between building
and its surroundings is influenced by building shape and building orientation.
- choose
a compact shape
Building Orientation
orientation of the building subject to
solar access:
- minimise
openings in sun-exposed facades (east and west facades)
- maximise
convective ventilation with high level windows and cross ventilation
(cross ventilation depends on building depth)
- shade
sun-exposed facades in summer, but passive solar heating is required
during winter months
- orient
building openings to the main wind direction in summer
- coastal
areas: use cooling breezes from the sea
Zoning of
Buildings
The main element is floor plan zoning to
maximise comfort for daytime activities and sleeping comfort:
- function
rooms are located in the north, whereas the living area is located in the
south
- locate
bedrooms for sleeping comfort to the east
- design
unobstructed cross ventilation paths
- locate
mechanically cooled rooms in thermally protected areas (coolest zone in
the house)
Exterior Building Elements
Similar to the architecture of dry
climates, it is good to use multi-layered wall and roof structures. The
exterior layer protects against solar radiation, which reduces heat absorption
of building elements. The interior layer minimises and retards thermal transfer
to the building's interior. This effect is called phase shift (siehe Glossar)
and amplitude attenuation (siehe Glossar). The thermal insulation protects
against heat in summer and prevents heat loss in winter.
Walls and
Roof
- multi-layered
wall and roof structures
- vapour
barrier should be placed on the inside or outside (In areas where you heat
more than air condition, do place the vapour barrier on the inside whereas
in areas where you air condition more than heat place the vapour barrier
on the outside)
- bright
reflective facades to reduce heat gain
- choose
jointless and airtight constructions
- choose
shape of roof, roof overhangs and roof drainage according local conditions
(amounts of precipitation and solar radiation)
- shade
building elements exposed to sun in summer
- thermal
insulation to prevent transmission heat loss in winter
Windows
- shade
all openings in summer and east and west openings year round
- glazing
with appropriate g-value (SHGC)
- glazing
with appropriate U-value
- adequate
window areas
- orientation
of windows and position of the window in connection with interior spaces
for good daylighting: clerestories, skylights and high windows improve the
brightness of a room; windows in the centre of the wall distribute the
light better in the depth of the room than corner windows
Shading
Shading devices are very important all
the year round. Include planting design to shade the building. Shading devices
have to be chosen according to window orientation:
- protection
against noon sun angle : horizontal shading (for south facades, northern
hemisphere)
- protection
against low hanging sun : vertical louvres or fins (for east and
especially west facades)
- there
are combinations of vertical and horizontal shading
For maximum solar gains, it is a wise
idea to choose adjustable shading devices wherever possible. Shade all windows
in summer and east and west windows year round.
Ventilation
Natural breezes are an essential element
of passive cooling. For this reason, it is important to include the flow of
cooling breezes through a building. Generally, cross ventilation is most
effective for air exchange in summer. Cross ventilation depends on the building
depth. Hence, design floor plans which do not block cooling breezes.
If possible, use coastal breezes for
cooling. Openings oriented to the sea improve the indoor climate.
Include convective air movement.
Convective air movement relies on hot air rising at the highest point, drawing
in cool air from shaded external areas. Higher room heights increase the
effect.
·
cross ventilation
·
include ceiling fans
to create air movement during still periods if necessary
4.
Dry Climates
Dry
climates are determined by high temperatures all the year round. Temperature
maximum is in summer, minimum is in winter.
basic constructional requirements:
- protection
against heat absorption and overheating
- protection
against direct solar radiation (humans and buildings), shades
- usage
of solar energy
- heat
storage by massive walls in day and night cycle
- optimised
A/V-balance small facade areas exposed to sun
- usage
of water and vegetation areas in order to improve the microclimate
- shading
of exterior spaces (plantings)
Building Location, Building Surroundings
The temperatures of building's
surrounding influence the annual amount of energy necessary to cool the
building.
- narrow
streets and alleys protect against hot winds
- build
the streets narrow so the buildings shade each other during the day
- use
vegetation, walls and banks as natural windbreak
- vegetation
around the building improves the microclimate (humidity, temperature,
dust, air pollutants)
- include
water bodies for evaporative cooling
Building Shape
Temperature compensation between building
and its surroundings is influenced by building shape and building orientation.
- compact
building shape, closed structure with small exterior areas
- include
atria and outdoor courtyards for (evaporative) cooling
Building Orientation
Orient the building with the short wall
facing west or southwest for the least solar gain in the summer.
- minimise
exterior areas exposed to the sun
- minimise
windows on east and west facades
- shade
building elements exposed to sun (roof, east and west facades)
- shade
building openings
Zoning of
Buildings
Floor plan zoning is very important.
Locate bedrooms for sleeping comfort on the east side of the building:
east-oriented rooms are only exposed to direct sun in the morning, so there is
enough time to release the absorbed heat until dusk.
- locate
bedrooms for sleeping comfort to the east
- provide
multiple flow paths and minimise potential barriers
Exterior
Building Elements
Multi-layered wall and roof structures
help to reduce the wall thickness of massive traditional architecture of hot
climates. The exterior layer protects against solar radiation, which reduces
heat absorption of building elements. The interior layer minimises and retards
thermal transfer to the building's interior. This effect is called phase shift
(siehe Glossar) and amplitude attenuation (siehe Glossar) and it is made
possible by thermal inertia of traditional massive wall structures or by
insulation materials.
Walls and
Roof
- multi-layered
wall and roof structures or massive structures of high thermal mass
- double
skin roof with a light outer layer with reflective surface
- vapour
barrier should be placed on the outside in case of mechanical cooling
- bright
reflective facades to reduce heat gain
- choose
jointless and airtight constructions in case of mechanical cooling
- shade
building elements exposed to sun (planting, roof overhang...)
Windows
- shade
all building openings
- appropriate
window areas (only small or no windows on east and west facades)
Shading
In hot and dry climates shading devices
are of special importance.
Shading devices have to be chosen
according to window orientation:
- protection
against noon sun angle : horizontal shading (for south facades, northern
hemisphere)
- protection
against low hanging sun : vertical louvres or fins (for east and
especially west facades)
- there
are combinations of vertical and horizontal shading
Building elements and openings exposed
directly to the sun should be shaded.
Ventilation
Due to high temperatures, natural breezes
often cannot be used for cooling the building. Using breezes for cooling
requires outdoor temperatures below 35°C. But it is possible to include
convective air movements (stack effect) for cooling. Traditional devices using
this effect are so called "wind catchers" (Persian: Badgir). Badgirs
can be found in Persia and Egypt.
5. Tropic Climate
basic constructional requirements:
|
Building Location, Building Surroundings
The temperatures of building's surrounding influence the annual amount of energy necessary to cool the building.
Building Shape
Temperature compensation between building and its surroundings is influenced by building shape and building orientation.
Building Orientation
Zoning of Buildings
The main element is floor plan zoning to maximise comfort for daytime activities and sleeping comfort:
|
Exterior Building Elements
The use of high mass construction is generally not recommended in hot humid climates due to their limited diurnal range. Passive cooling is generally more effective in low mass buildings, because lightweight construction responds more quickly to cooling breezes.
Insulated roofs might be advantageous. Insulated walls are only necessary in case of artificial cooling. Otherwise, heat accumulation might be the result.
Walls and Roof
Tropical cyclones are an accepted part of life in some tropical areas. These thunderstorms or cyclones cause pressure on surfaces of buildings, which leads to loads on the structure. Hence, there are structural materials standards to select elements that can resist the required wind actions. A large number of structural elements must be functioning correctly to avoid wind damage caused by pressure and suction. Tropical thunderstorms often come along with heavy downpours. So there might be a need for circumferential drainage in order to protect the building against undercutting.
Windows
ShadingIn tropic climates shading devices are of special importance.
Shading devices have to be chosen according to window orientation::
Shade sun-exposed external surfaces and all building openings. Choose endemic plants for shading. Plants create pleasant filtered light and assist cooling by evaporation.
|
Ventilation
High temperatures and high humidity require maximum ventilation to reduce heat and humidity loads. Natural air flow may contribute to cooling:
|